Florida County Water Hardness Reference

County GPG Hardness Flush Every
Collier 17.5 Extreme 6 mo
Miami-Dade 15.5 Extreme 6–7 mo
Palm Beach 14.5 Very Hard 7–8 mo
Lee 14.0 Very Hard 7–8 mo
Monroe (Keys) 14.0 Very Hard 7–8 mo
Broward 13.5 Very Hard 8 mo
Charlotte 12.5 Very Hard 8–9 mo
Osceola 10.0 Hard 10 mo
Sarasota 10.0 Hard 10 mo
Orange 9.0 Hard 11 mo
Hillsborough 6.5 Moderate 14 mo
Pinellas 5.5 Moderate 16 mo
Duval 4.5 Moderate 18 mo

Intervals assume no softener, medium household usage. A softener reduces the interval by 40–60%.

Scale Buildup — What It Costs You

  • 1/16" scale (early): 12% efficiency loss — $15–25/mo extra gas cost
  • 1/8" scale (moderate): 25% efficiency loss — error codes beginning
  • 3/16" scale (heavy): 40% efficiency loss — frequent shutdowns
  • 1/4" scale (severe): heat exchanger replacement — $400–$900 part
  • Full scale block: unit failure — replace entire unit $800–$2,500
  • Annual descaling cost: $120–$280 (DIY: $15 in vinegar)
  • Warranty note: most warranties void if scale damage with no flush records

Step-by-Step Tankless Descaling Flush

Applies to units with service/isolation valves on the cold inlet and hot outlet. If your unit lacks them, a plumber must install them first. Total time 60–90 minutes; works on all major brands (Rinnai, Navien, Rheem/Ruud, Noritz, Bosch, Takagi).

Equipment: 5-gallon food-grade bucket (~$8); submersible utility pump 1/6 HP+ ($15/day rental or $35–$65); 1–2 gallons white distilled 5% vinegar (never apple cider or cleaning vinegar — additives damage seals; 2 gallons for S. FL extreme hard water); two descaling hoses with 3/4" garden hose fittings (descaling kit $15–$25); rubber gloves and safety glasses.

Procedure: 1. Turn off gas/power. Gas units: close the gas shut-off valve. Electric: switch the dedicated breaker OFF. Verify de-energized (no pilot light / status lights). (~2 min) 2. Close the cold inlet and hot outlet service valves (blue = cold, red = hot) perpendicular to the pipe to isolate the unit. (~2 min) If the unit lacks service valves, do NOT proceed. 3. Release pressure — open a nearby hot water faucet 10–15 sec, then close. (~1 min) 4. Connect the descaling hoses — remove the flush port caps on both service valves; hose 1 from pump outlet to cold inlet flush port; hose 2 from hot outlet flush port to the bucket; place pump in the bucket. (~5–10 min) 5. Fill bucket with white vinegar and start pump — 1 gallon (1.5–2 gal for Collier/Miami-Dade); open both flush-port valves (main valves stay closed); start pump. Vinegar circulates bucket → pump → cold inlet → heat exchanger → hot outlet → return → bucket. Discolored (tan/brown) solution and scale particles appear within 5–10 min. (~45–60 min run) 6. Circulate 45–60 minutes — 45 min for moderate scaling; heavily scaled units (S. FL, infrequent service) run 60 min then drain and repeat with fresh vinegar for 30 min more. Darkening solution confirms it's working. 7. Stop pump, drain vinegar, flush with fresh water — close flush-port valves, disconnect hoses, replace caps; open the cold inlet main valve slowly to push remaining vinegar out the open hot faucet; flush 3–5 min until clear and odor-free; open hot outlet main valve. (~10 min) 8. Restore power/gas and test — clear error codes; unit should ignite within 3–5 sec with stable flow/temperature. If codes persist, professional service may be needed. (~5 min) Record the flush date.

Post-Flush Checklist: Both main service valves fully open; flush port caps replaced; no vinegar odor at hot taps (run 2–3 min); no error codes on display; unit ignites promptly (3–5 sec); flush date recorded.

Tankless Water Heater Scale Error Codes

FL's high-GPG water accelerates scale buildup — most FL tankless units hit scale codes 2–3× faster than national averages.

Rinnai: - LC / LC0 (Descale Now): Preventive maintenance reminder triggered by the flow-hour counter (LC0 = first warning); unit still functions. In FL hard water counties, LC0 typically triggers at 6–8 months. Fix: descaling flush, then reset (hold On/Off 5 seconds). - LC1–LC9 (Service Needed): Progressive scale accumulation. LC1–LC3: descaling typically resolves. LC4–LC6: significant scale; professional check recommended. LC7–LC9: severe — heat exchanger damage possible; professional service required. In S. FL extreme hard water, units can progress LC0→LC5 within 12–18 months without descaling. - Code 16 (Overheating): In FL frequently caused by scale-restricted flow rather than ambient overheating. If last descale was >6 months ago in S. FL, descaling is the likely fix; if it returns within days, heat exchanger/sensor damage may exist.

Navien: - E003 (Ignition Failure): Can be scale-induced — scale reduces flow below the minimum activation threshold, preventing ignition. Confirm gas supply first; if good, descale; if E003 persists, igniter/flame rod service. - E012 (Outlet Temp Too High): Almost always scale restricting flow in FL hard water — the single most common hard-water code in FL Navien units. Descale immediately; clears after a complete flush. - E016 (Abnormal Outlet Temp): Navien's direct scale-detection error; in FL almost exclusively caused by scale. Descale immediately; consider a softener or NaviCirc afterward.

Rheem / Ruud: - P1 (Descale Now): Maintenance reminder based on usage hours; typically triggers ahead of national schedule in FL. RTGH-series and Performance Platinum commonly show P1 within 6–8 months in S. FL without a softener. Descale then reset per model manual. - Code 13 (Exhaust High-Limit): Often venting (blocked vent/length), but in FL can be scale-induced. Inspect vent termination (birds' nests/debris common in FL); if clear, descale. - C7 (Condensate Drain Issue): Scale from FL hard water can block the condensate drain on condensing models, pooling acidic water inside. Inspect/clear the condensate line; flush with vinegar; if overflow visible, professional service.

Noritz: - Code 11 (No Ignition / Flame Failure): Often scale-induced flow restriction below the ~0.5 GPM minimum for ignition. Confirm gas; if OK, descale. - Code 12 (Flame Failure During Operation): Scale-restricted flow drops below the activation threshold mid-cycle (intermittent hot water). Descale; if it persists, flame rod/igniter/gas valve service. - Code 73 (Scale / Water Quality Alert): Direct scale maintenance reminder; in FL hard water (>10 GPG) typically triggers within 8–12 months. Descale, then manually clear in service mode (hold Up + OK 5 seconds in off state on many models).